EKG Remediation of Embankment

Forest of Dean slope stabilisation

Low Impact Benefits

Highway Embankment Stabilisation

Sewage Sludge

Mine Tailings

Railway Embankment Stabilisation

Reinforced Soil

Lagoon Consolidation

Consolidation of Soft Soil

 

Consolidation of super Soft Soil

EKG has been used in the form of an electrically conductive prefabricated vertical drain (e-PVD), to consolidate super soft kaolin clay. A large test pit was filled with kaolin clay with a moisture content of 85% to a depth of 2.4m with EKG vertical drains installed as shown in. The clay was left to settle for 100 hours, resulting in a consolidation of 20mm.

Electroosmosis was then applied for a period of 500 hours which produced further consolidation of 340mm and an increase in shear strength from < 1kN/m² to 15–30kN/m². To produce an equivalent result using conventional means would have required a surcharge loading of 10m of fill, which would have been impossible to place on the super soft soil.

During electro-osmosis water flows from the anode to the cathode; as a result the area around the anodes experiences the greatest reductions in moisture content and improvement in shear strength. In order to minimise moisture content anisotropy, the trial was completed with a phase of polarity reversal in order to draw water away from the electrodes which were acting as anodes in the first phase. Polarity reversal resulted in a more even distribution of shear strength in the soil.

Large lab scale consolidation of super soft soil using EKG

 

Day 1 - 85% water content and undrained shear strength = 1.5 kPa

24 days
normal polarity
 
   
   
  16 days
reverse polarity

 

   

Day 40 - 62% water content / undrained shear strength = 35 kPa

 

The trial demonstrated that dewatering/consolidation using EKG prefabricated drains is rapid, effective and, energy efficient. For full scale applications, consolidation by EKG has a number of potential advantages over conventional wick drain technologies:

• it is faster

• no surcharge is required

• the effectiveness of the e-PVD is unaffected by kinking or smearing as consolidation proceeds

 

 

Home | EKG Dewatering | EKG Slope Stabilisation | EKG Technology | EKG News | Case Studies | Downloads | Contact | Sitemap